These Fire Door Deficiencies Require a Fire Door Replacement

 Fire Door Inspection is the first step to know every detail required for it’s repair or replacement. Knowing the detailed list of deficiencies will provide you a help to know the expenses of repairing as well as replacement. So, always pick the annual fire door inspection rather than waiting for a long time to prevent a mishap. Most of the time, common minor repairs require which includes.

  • Gap adjustment
  • Installation of smoke seals
  • Hinge replacement
  • Oiling in parts
  • Silencer replacement
  • Strikes for lock sets and panics


These are some of the things that can be taken care of without spending much on it that ensures the prevention from big hazards.

Incorrectly fitted fire door

Fire doors require proper fitting and smoke seals are a vital part of it which prevents any property from the hazardous fire. An improper fire door fitting may cause the seepage of smoke and that further can be hazardous to the lives of people. So, you always check the fire door seals.   

Damaged fire door

A damaged fire door should be repaired properly that may lead to its effectiveness. Inspection may lead to identifying the damaged part and rendering its effectiveness. To ensure its full working order, regular checks are required. Recent checks showed that over 15% had damage to the door leaf as well as other components.

Improper signage

During the findings, one third of the fire doors are found to have incorrect signage. Incorrect signage may lead to the door with ineffective performance which may be hazardous to the people off the building.

Missing fire door labels

A label on the fire door should be visible or legible but sometimes, it may be stamped or diecast into the door or frame. These labels are an integral part of every fire door which should be re-labeled by a listing agency.

Gap Adjustment

It is important to check there gaps between fire doors around the top sides of the doors which should be less than 4mm once they are closed.Under the door, it can be 8mm. The lesser gap between the doors may seize the smoke from traveling beyond.

Inspection and examining it properly is necessary so that it can be fixed to withstand any hazardous fire. Fixing costs can’t go higher if regular checks have been done properly.